![]() Note: because of recent updates to the ASI Console application to allow use of the application offline, an older installed version on your machine, or parts of it, may not run. This is because of the need for older versions to connect to the internet and compare with the version on our website. We have removed this requirement, and in the process removed the functionality from our website to verify the current version. This was done to better service facilities that have restrictions on computers in laboratories and research settings not allowing internet access. The resolution is: 1. Uninstall the ASI Console application from your machine using Control Panel -> Programs 2. Download the latest version from this page following the directions above. This version will not attempt to interact with the internet and should function properly as a stand-alone application. When the MS-2000 is connected to the serial port, you can use the buttons to move the stage. Using the text window on the right, you can control and configure the MS-2000 by entering commands defined in the That document also explains the functions of the HOME and ZERO buttons and all other functions of the MS-2000. You can set some configuration items by using the buttons, drop-down menu, and text box at the lower right of the MS-2000 panel. In a similar way, the FW-1000 can be controlled and configured by using the FW-1000 panel. The drop-down list “Select a COM port” displays all ports available and not currently in use by other applications. If you don’t see your preferred port on the list, then one of the following conditions exist: • The port is in use by another application. Disconnect or exit the other application, and try again. • The connection is a USB virtual serial port implemented by MS-2000′s built-in Silicon Labs USB-serial bridge, and the connection is not ready for use. To be ready for use, the MS-2000 power must be on, the USB cable connected, and the Silicon Labs USB-Serial drivers installed. To download and install the drivers, go and follow the instructions titled “ASI-branded USB Driver Installation Steps (Choice 1)”. • The port is absent or disabled. Everything what you will need for ASI camera control, imaging, guiding and processing at one place! Windows, MAC and Linux USB drivers, ASCOM drivers, latest firmware and camera control and processing software for all ZWO devices. Use the drop-down list “Select a product type” when you need to update firmware in a product other than the MS-2000. Click “Next >”. The “Connect and Load” panel appears. If the panel looks like figure 9, then do one of two things, depending on what kind of connection you are using: USB connection: Press the Reset button on the MS-2000 back panel. If this does not work then you have to either use a real serial port or use a serial adapter, e.g., Keyspan™ USA-19HS Serial Adapter. Serial adapters can often be obtained at local stores. Serial port connection: Turn power off then on again. Aoc e2251fwu driver for mac. Note that as soon as the panel looks like Fogure 10 the firmware is being erased. If using a USB connection, do not disconnect, turn off power, or otherwise interrupt the firmware loading when the panel looks like Figure 10. 802.11n wireless usb adapter. To do so will make firmware loading impossible with the USB connection. If the direct USB connection stops working due to loss of firmware, the Keyspan USB-serial adapter will work. This dialog prepares a set of commands used by the MS-2000 Sequencer firmware. Under control of Sequencer firmware, the MS-2000 can perform sequences of moves and emit triggering signals under the control of preloaded instructions. Those instructions include conditional statements based on internal and external events such as input trigger signals and counters. The Sequencer was conceived as a way to do real time image acquisition controlled by camera triggering signals and millisecond resolution internal timers, thus bypassing unpredictable latencies characteristic of host computers. The Sequencer firmware can be obtained from ASI and loaded into any MS-2000 controller whose Model identifier (on the bottom of the unit) is prefaced by “WK”. Some additional hardware is needed from ASI if multiple trigger signals are to be used.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |